Cross the truss on the lower side not between the metal and truss but through the truss and clamp it in the protected corner area of the truss.
Run romex through roof truss web.
What are the code requirements for nm cable nonmetallic sheathed cable or romex in an attic.
The second floor of my shop is built with attic trusses which integrate the floor joists with the truss.
I want to run 6 3 wire from my main panel down through the wall across the house through the crawl space and out to a spa panel.
Leave one bare ground wire long and snip the rest to 6 in.
Pitched roof with rafters balcony at my house.
Pick a board that runs close to the corner webbing of the truss if possible.
I would staple the wire to the bottom of the floor joists and run it up through the wall and directly to the spa panel.
When romex is run across rafters in an open unfinished attic it is my position that a raceway of some kind 1x3 s or even 2x4 s should first be attached across the affected rafters perhaps 3 to 4 above the joists then the wiring be stapled to the raceway.
I am installing some led lights in my shop and don t want to drill holes into the floor joists in order to run the romex.
Can i run romex on the underside of the joists with cable staples every 24 inches.
My attic is non accessible so i know for a fact that i must protect the romex with guard strips or bore holes 1 25 from the face of the joists when running perpendicular to the joists and when i run parallel i must staple the romex to the face of the joists.
Hi all i have to run some romex in my attic.
That way the wire is in a protected underside corner where nothing could hang on top of it as it crosses the truss.
Fold the ground wires neatly into the back of the box photo 11.
Sunday july 15 2018.
Where run across the top of floor joists or within 2 1 m 7 ft of floor or floor joists across the face of rafters or studding in attics and roof spaces that are accessible the cable shall be protected by substantial guard strips that are at least as high as the cable.
Do i need to run the romex wiring through a conduit if i m running the wiring through wooden studs or is it acceptable to run the romex as is horizontally behind the drywall of a bedroom.
If you ve got a quick question you can try to get an answer from sites that say.