If the cut plane on you lighting plan is at 0 change it to 1 2 someting higher than 0 so that it slices through the bottom of the spaces.
Room not visible through roof revit.
When using the room tag command in a revit host model there is no room displayed to tag from the linked model the phase of the view in the host model does not match the phase that the room was created in.
Hi all hoping someone can help.
The rooms do show up in the room schedule i just tried deleting them from the schedule and placing them again in the plan but it gives me the same message that the element i created does not show up in this view.
This makes the roof line visible in the plan view but the lines appear as solid lines.
Revit displays the modify linework contextual ribbon.
This is because with the areas and volumes option selected default setting the vertical boundary of the space will snap to room bounding components such as roofs.
If this is the case the easiest solution is to select the room group it change reference level under properties while still in group and then ungroup.
All rooms show in their appropriate plans if i turn on interior fill in vg except the 6th floor open office room and tag.
I have a rouge room.
If the phase names differ between the host and link check the phase mapping setup for the link.
So i have a floor level at 0 with a few rooms and a sanctuary level with only one room.
Put a section through the room go to the section view and make sure the room has it interior fill checked.
In the view properties expand the underlay drop down and select the level on which the roof was created to display as an underlay.
Weird problem i m not sure how to explain it.
The rest of the floor plate is open office.
This might flag that the room starts at a higher level than your cut plane.
Use them sparingly and primarily to define spaces where there are no walls like a waiting area in a lobby.
We are using scope boxes.
If the spaces are not visible with them turned on in v g ensure that the cut plane is cutting through the spaces as they will not show unless this is so.
2012 02 15 08 00 pm 3.
The room is placed because i can see it in the section just not in any of the plan views.
The project is a 6 story open office building with two vertical circulation cores and a utility restroom core.
All the other rooms on this floor are visible.
Select the linework tool in the view panel on the home ribbon.
Take care to place room separation lines so they connect with the loc line of walls.
If the upper limit and offset are specified beyond the level above the roof the vertical boundary of the space will snap to the roof even though the upper limit is higher than the roof.
None of my room colours are showing up.